CAN/CSA C22.2 NO. 60601-2-22:23 PDF

CAN/CSA C22.2 NO. 60601-2-22:23 PDF

Name:
CAN/CSA C22.2 NO. 60601-2-22:23 PDF

Published Date:
03/27/2023

Status:
Active

Description:

Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment (Adopted IEC 60601-2-22:2019, fourth edition, 2019-11, with Canadian deviations)

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$95.7
Need Help?

CSA Preface 

This is the fourth edition of CSA C22.2 No. 60601-2-22, Medical electrical equipment — Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-2-22 (fourth edition, 2019-11). It supersedes the previous edition, published in 2008 as CAN/CSA-C22.2 No. 60601-2-22 (adopted IEC 60601-2-22:2007). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CSA C22.2 No. 60601-2-22" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC Standard 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health and Well-being. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. 

Scope and object 

Clause 1 of the general standard1 applies, except as follows: 

201.1.1 Scope Replacement: This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of laser equipment for surgical, therapeutic, medical diagnostic, cosmetic or veterinary applications, intended for use on humans or animals, classified as LASER PRODUCT of CLASS 1C where the ENCLOSED LASER is of CLASS 3B or 4, or CLASS 3B, or CLASS 4. MEDICAL ELECTRICAL EQUIPMENT or MEDICAL ELECTRICAL SYSTEMS which incorporate lasers as sources of energy being transferred to the PATIENT or animal and where the lasers are specified as above, are referred to as "laser equipment" in this document. NOTE 1 LASER PRODUCTS for these applications classified as a Class 1, Class 1M, CLASS 2, Class 2M or CLASS 3R LASER PRODUCT, are covered by IEC 60825-1:2014 and by the general standard. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies to ME EQUIPMENT and to ME SYSTEMS, as relevant. Hazards inherent in the intended physiological function of laser equipment within the scope of this document are not covered by specific requirements in this document except in 7.2.13, Physiological effects, of the general standard. 

NOTE 2 See also 4.2, RISK MANAGEMENT process, of the general standard. 

NOTE 3 If the laser equipment is CLASS 1C according to IEC 60825-1:2014 and is used as a laser appliance in a household, it is covered by IEC 60335-2-113:2016. 

201.1.2 Object Replacement: The object of this document is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for the safety of surgical, cosmetic, therapeutic and diagnostic laser equipment.


Edition : 4th
File Size : 1 file , 2.7 MB
ISBN(s) : 9781488347481
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 91
Product Code(s) : 2430797, 2430797
Published : 03/27/2023

History

CAN/CSA C22.2 NO. 60601-2-22:23
Published Date: 03/27/2023
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment (Adopted IEC 60601-2-22:2019, fourth edition, 2019-11, with Canadian deviations)
$95.7
CAN/CSA C22.2 NO. 60601-2-22-08 (R2018)
Published Date: 12/01/2008
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment (Adopted IEC 60601-2-22:2007, third edition, 2007-05)
$53.4
CAN/CSA C22.2 NO. 60601-2-22-01 (R05)
Published Date: 06/01/2001
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Diagnostic and Therapeutic Laser Equipment (Adopted CEI/IEC 601-2-22:1995, second edition, 1995-11)
$30

Related products

CAN/CSA C22.2 NO. 60601-1-6:11 (R2021)
Published Date: 12/01/2011
Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability (Adopted IEC 60601-1-6:2010, third edition, 2010-01)
$50.4

Best-Selling Products

Reinforced Concrete Detailer's Manual
Published Date: 01/01/1971
$8.4